Ekrem Rexha Lower Secondary School, Lubizhdë

Municipality: Prizren
Project type: School
Investment value: €183,327.11
Year: 01/05/2023
Area: 1,520.00
Status: Përfunduar
Electricity consumption before implementation of EE measures: KWh/vit: 268,500.00 MWh/vit: 204.85
Electricity consumption after implementation of EE measures: KWh/vit: 63,910.00 MWh/vit: 63.91
Electricity savings after implementation of EE measures: KWh/vit: 204,850.00 MWh/vit: 204.85
Savings percentage: 76%
CO₂ reduction (tons/year): 16.2

Implemented Measures

  1. Thermal insulation of external walls

  2. Thermal insulation of the roof

  3. Replacement of doors and windows

  4. Replacement of lighting fixtures with LED ones

  5. Automation of the heating system

  6. Renovation of the heating network

  7. New pellet boiler